F-Sorb X400CE series
surface area and porosity analyzers are new generation instruments which were
researched and developed by Gold APP Instruments Corporation and China weapons
institute. Innumerable independently patented techs make Gold APP instruments
enjoy great popularity at home and abroad. A high level of precision and
resolution, complicity of operation, speed, compact size, and their stability
guarantee our analyzers equally appropriate to industry quality control,
institutes, universities and laboratories. The weapons system’s high demands
and imported parts with original packaging had greatly improved instruments’
reliability and life. The high cost performance of F-Sorb X400CE series
analyzers easily ensure your investment profits and flexible equipped peripheral
can satisfy different users’ demands.
F-Sorb 2400CE adopts
speed and efficient continuous flowing gas (nitrogen) adsorption principle, is
an expert for contrast reference materials method, single and multi-point BET
method and Langmuir method analysis. BET method is universally recognized and
the most commonly used way for nitrogen adsorption surface area analysis. No
need of reference materials (RM) and utilizes sorption with incorporates
multilayer coverage to calculate surface area. Speedy testing, high cost
performances and easy operation make F-Sorb 2400CE be a desirable assistant for
quality control in production field, research institutes and universities.
F-Sorb 2400CE BET surface area analyzer parameters
Measuring Method: reference
materials method, single and multi point BET method, Langmuir surface area, adsorption
and desorption isotherm, average particle size estimate, carbon black external
surface (STSA), adsorption constant C analysis etc.
Measuring Ranges:
0.01 m2/g to no known upper limit (surface area)
Accuracy:
repeatability errors ≤1%
Analysis Control: 7
inch high sensitive color touch screen with built-in PC operation system,
providing USB linked keyboard and mouse; external PC is supportable by RS232
communication port for a larger operation interface; can be easily and quickly
switched between two modes.
Safety Cover:
transparent cover can protect operators be hurt by liquid nitrogen splash; also
can reduce liquid nitrogen volatilization, extend its testing time and save
your cost; more important is the cover can isolate foreign environment
influences to the analysis procedures, naturally, improve data stability and
accuracy.
Flow Rate Adjust:
Gold APP Instruments patented F-Sorb micro stepping motor can realize flow rate
auto-adjust for every P/Po point in BET analysis; flow rate value
auto-collected by software and real-time displayed in interface
Quantitative Dosing:
patented F-Sorb quantitative pipe TM desorbs automatically, realized
auto dosing for sample desorption isotherm, manual pipeline switch is not
required
Manifolds Sealing: high
vacuum system with stainless steel manifolds, sound sealing performance can
eliminate errors caused by gas molecules permeation
Sample Types:
powders, particle, fiber, flakes and other species
Sample Ports: 4
samples simultaneously
Analysis Gases:
high purity (99.99%) Helium as carrier; Nitrogen (99.99%) as adsorbate; Ar,
Kr etc. are optional
Time: less than 5 minutes for
every P/Po point’s adsorption and desorption; analysis data will
present automated by Gold APP softwareTM
Pressure Required: atmospheric pressure, no need vacuum, save experiment time
Data Acquisition:
high precision and integration chip, minimal errors, strong anti-interference
ability
Data Reduction:
Windows®-base independently developed Gold APP softwareTM, perfect
versatility, ease of use and multi-model data reduction reports
Operation System:
multifunctional, fully automated, highly intelligent operation system
F-Sorb 2400CE BET surface area analyzer features:
Fully
automated, farewell to complex manual operation; minimal user intervention; promote efficiency.
A. Structure Design
1. Stainless manifolds
system is much better than plastic manifolds, obviously enhances sealing
performance, eliminates errors caused by gas molecules permeation, no ageing
for manifolds, increase reliability and prolong life, more appropriate for
humid environment.
B. Control System
1. Integrated
multifunctional control system; motor screw rod lifting system ensures Dewar stability.
2. Innovated balanced
bridge circuit greatly improves signal voltage sensitivity, as well as achieves
auto balance of signal zero drift.
3. Fully-auto operation,
minimal operator involvement and work efficiency improved.
C. Data Acquisition and Reduction
1. High precision data
acquisition and signal amplification, high integrated A/D transformation
system, strong anti-interference ability and high real time, can reduce
environmental influence on analysis procedures.
2. Utilize super
sensitive thermal conductivity detection and balance system can increase detectable
signal range; zero drift auto calibration system enhances stability and
accuracy.
3. Independently
innovated Windows® compatible software, versatile applications,
flexible customer-tailor interface, ease of use; self developed data reduction
module can efficiently eliminate system errors and improve precision.
4. Customer made data
reports and diversified data calculation models are convenient for data
analyzing; powerful data archiving and searching capacity helps a lot for data
management.
D. Analysis Optimize
1. Multi analysis methods,
no need to convert operations frequently, all set in dedicated software.
2. Contrast reference materials
method and BET method can switch freely, simplify operation steps and improve
measurement efficiency.
3. Pioneered gas amount
auto-adjust system brings extremely accurate, stable and no user intervention
analysis.
4. Can be upgraded to
F-Sorb 3400CE.
1. Super micro powder,
nanomaterials, particle and fiber shaped surface area analysis.
2. Product quality
control for powder species related corporations.
3. Research institutes,
universities for BET theory teaching.
4. Full cells, catalysts,
additives, adsorbent, ceramics, magnetic materials, energy storage materials
etc.
5. Other researches
concern surface area performance.
Contact info:
Email: sales@jinaipu.com
Tel.:
0086-10-82133318 Ext.810
Fax:
0086-10-82118197
Mobile:
0086-18210009838
IMs:
Skype: